Megaraid storage manager download windows 10






















It eliminates most, if not all of the shortcomings found in legacy file systems and hardware RAID devices. Once you go to ZFS, you will never want to go back. The NAS4Free operating system can be installed on virtually any hardware platform to share computer data storage over a computer network. Thanks to the modular design of the framework it can be enhanced via plugins. It is a simple and easy to use out-of-the-box solution that will allow everyone to install and administer a Network Attached Storage without deeper knowledge.

Online Capacity Expansion Online Capacity Expansion OCE allows the capacity of a virtual disk to be expanded by adding new physical disks or making use of unused space on existing disks, without requiring a reboot.

Fast initialization for quick array setup Fast initialization quickly writes zeros to the first and last sectors of the virtual drive. Consistency check for background data integrity Consistency check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. Extensive online configuration options and advanced monitoring and event notification Management tools provide convenience for the configuration of logical volumes and alerting when errors have occurred or are about to occur.

Patrol read for media scanning and repairing Patrol read is a background sentry service designed to pro-actively discover and correct media defects bad sectors that arise normally as a disk drive ages. Global and dedicated hot spare with revertible hot spare support A hot spare rebuilds data from all virtual disks within the disk group in which it is configured.

WebBIOS configuration utility for pre-boot array configuration and management WebBIOS is a utility that is built into the ServeRAID controller that allows you to configure drive groups and logical drives before installing or booting the operating system. Up to 63 drives are supported in a JBOD configuration. JBOD drives can be used as bootable drives. Table 2. Primary feature upgrades. Server support The following tables list the servers that support the M and Me. Support for System x and dense servers with Intel Xeon v3 processors Table 5.

Support for servers with Intel Xeon v2 processors Table 6. Table 7: 1. Table 8. Table 9. Table Operating system support The adapter supports the following operating systems: Tip : This table is automatically generated based on data from Lenovo ServerProven.

Width: 69 mm 2. Book Contents Book Contents. Find Matches in This Book. PDF - Complete Book 2. Updated: June 15, Display controller, virtual drive, physical drive, and battery backup unit BBU properties, and change parameters. Delete virtual drives. Migrate a storage configuration to a different RAID level. Detect configuration mismatches.

Import a foreign configuration. Scan devices connected to the controller. Initialize virtual drives. Previous—Click to return to the previous window that you were viewing. Turn off alarm—Click to turn off the sound from the onboard controller alarm. You can then view information about the controller and the devices connected to it, or create a new configuration on the controller.

For more information, see. Virtual Drives Alt-v —Views the Virtual Drives window, where you can change and view virtual drive properties, delete virtual drives, initialize drives, and perform other tasks. Drives Alt-d —Views the Drives window, where you can view drive properties, create hot spares, and perform other tasks.

Configuration Wizard Alt-o —Starts the Configuration Wizard and creates a new storage configuration, clear a configuration, or add a configuration. Events Alt-e —Views system events in the Event Information window.

Step 2 Choose a configuration type:. Caution If you choose Clear Configuration or New Configuration , all existing data in the configuration is deleted. Back up data that you want to keep before you choose a configuration type.

The following number of drives is required: New RAID 5 virtual drives must have at least five drives for a background initialization to start. New RAID 6 virtual drives must have at least seven drives for a background initialization to start.

We recommend that you use either a battery to protect the controller cache or an uninterruptable power supply UPS to protect the entire system.

If you do not use a battery or a UPS, and there is a power failure, you risk losing the data in the controller cache. Caution LSI allows Writeback mode to be used with or without a battery. LSI recommends that you use either a battery to protect the controller cache or an uninterruptable power supply UPS to protect the entire system. Policies area—Lists the virtual drive policies that were defined when the storage configuration was created.

For information about these policies, see Using Manual Configuration. Operations area—Lists operations that can be performed on the virtual drive.

Choose from the following options and click Go to perform an operation: — Delete —Deletes this virtual drive. Caution Before you run an initialization, back up any data on the virtual drive that you want to save. All data on the virtual drive is lost when you initialize the drive. Caution Before you change a virtual drive configuration, back up any data on the virtual drive that you want to save. Viewing Physical Drive Properties and Operations The Physical Drive window displays the properties of a chosen drive and then enables you to perform operations on the drive.

To view drive properties and perform subsequent operations, follow these steps: Step 1 To access the Physical Drive window, choose one of the following options: In the main WebBIOS CU window, in the Physical Drives area in the right side , click a drive. The Physical Drive window appears. Then click a drive in the right pane. Step 3 If the drive state is Online , choose one of the following operations and click Go : MakeDriveOffline —Forces the drive offline.

This window contains the following information: Battery information Design information Capacity information Auto Learn properties and settings Most of the Battery Module properties are view-only and are self-explanatory. Managing RAID This section includes information about maintaining and managing storage configurations. Expanding a Virtual Drive You can increase the size of a virtual drive to occupy the remaining capacity in a drive group. Monitoring Array Health You should periodically run a consistency check on fault-tolerant virtual drives.

The consistency check begins. Recovery MegaRAID Recovery, also known as Snapshot, offers a simplified way to recover data and provides automatic protection for the boot volume. Caution Do not select the virtual drive containing the operating system OS as the Snapshot Repository. Updates to the operating system or operating system crashes could destroy data on that virtual drive. Deleting a Virtual Drive You can delete any virtual drive on the controller if you want to reuse that space for a new virtual drive.

Caution Back up any data that you want to keep before you delete the virtual drive. Migrating an Array to a New Server A foreign configuration is a storage configuration that already exists on a set of drives that you install in a server.

Foreign Configurations in Cable Pull and Drive Removal Scenarios If one or more drives are removed from a configuration, for example, by a cable pull or drive removal, the configuration on those drives is considered a foreign configuration by the RAID controller. Original Number of Drives in the Drive Group. Caution Back up any data that you want to keep before you change the RAID level of the virtual drive.

If you do not have a record of which option is used in your server, you can read the on-screen messages that are displayed during system bootup Information about the card models installed are displayed as part of the verbose boot. Step 5 Press F when you see the following on-screen message: Foreign configuration s found on adapter. All of the disks from your previous configuration are gone. If this is. N Virtual Drive s found on host adapter.

Limitation on Importing Foreign Configuration To a Virtual Disk That is Under Construction Limitation When the reconstruction operation of a virtual disk VD is in progress and the controller fails or the VD changes to an offline state, you cannot import the foreign configuration and the VD cannot be recovered. The limitations of this design are as follows. The RLM operation cannot be aborted once started. If all of the VDs that are undergoing the RLM operation change their state to offline drives are pulled out or the enclosure powers off and then if drives return, the VD is foreign and in offline state.

Then the VD enters into the morphing state. Prerequisites For Reconstruction to Start Firmware performs checks before starting the reconstruction operation on a VD. It fails the reconstruction command if any of the following conditions exist: Reconstruction is already active multiple reconstructions are not allowed.

Rebuild operation is active. Copyback operation is active. Check Consistency is active. Background Initialization is active. Virtual drive initialization is active. Both have been plugged in for a couple of days so it should have had pleanty of time to charge. ETA 3 to 6 Weeks. To determine if your server supports this program, refer to the Product Notes for your platform. With self-encrypting drives 1GB cache memory. The monitoring of the server hardware, especially the individual data carriers including RAID controller and configured RAIDs, plays a major role in the administrative daily routine.

It addresses the growing demand for increased data throughput and scalability requirement across the enterprise-class server platforms. Hi Storage. Max driftstemperatur. Onboard switching regulator circuitry operating from the 3. Originally ran just stock kernel. Their utilities are pretty solid. Secondary controller: M. Note This menu option does not appear when the server has no M. Step 3 Press F10 to save your changes and exit the utility.

Step 2 Choose the Advanced tab. Click the release number that you are downloading. Click the Download icon to download the drivers ISO file. Step 2 Continue through the subsequent screens to accept the license agreement and then browse to a location where you want to save the driver ISO file. Copy the expanded folder to a USB thumb drive. Step 3 Start the Windows driver installation using one of the following methods: To install from local media, connect an external USB DVD drive to the server and then insert the first Windows installation disk into the drive.

Step 5 Power cycle the server. Step 6 Press F6 when you see the F6 prompt during bootup. Connect the USB thumb drive that you prepared in Step 3 to the target server. On the Windows Load Driver dialog, click Browse. Step 4 On the Driver tab, click Update Driver to open the Update Device Driver wizard, and then follow the wizard instructions to update the driver.

The drivers do not support updates to those OS kernels. Preparing Physical Thumb Drive for Linux This topic describes how to prepare physical Linux thumb drive from the driver image files. Step 2 Extract the dud.

Step 3 Copy the driver update disk image dud-[driver version]. Step 5 Create a directory and mount the dud. Note An. Note Map the. Step 5 Power-cycle the target server. Note Do not press Enter in the next step to start the installation. Step 11 Below Driver disk device selection , select the option to install your driver. Note The installer recognizes the driver file as an.

In the following example, type 6 to select device sdb: 5 sr0 iso RHEL Step 12 Under Select drivers to install , type the number of the line that lists the megasr driver. Step 16 After the installation completes, reboot the target server.

The SLES installation begins when the image is booted. Step 9 Press e to edit installation parameters. Verify installation of the driver when you reach the Suggested Partitioning screen: On the Suggested Partitioning screen, select Expert Partitioner. Step 14 When installation is complete, reboot the target server.

Was this Document Helpful? Yes No Feedback. Do not mix controller types in the server.



0コメント

  • 1000 / 1000